R&D: Segmented Media and Medium Damping in Microwave Assisted Magnetic Recording

Methodology of segmented media stack design for MAMR

AIP Advances has published an article written by Xiaoyu Baia, and Jian-Gang Zhu, Carnegie Mellon University, Pittsburgh 15213, USA.

Click to enlarge


Abstract
:
In this paper, we present a methodology of segmented media stack design for microwave assisted magnetic recording. Through micro-magnetic modeling, it is demonstrated that an optimized media segmentation is able to yield high signal-to-noise ratio even with limited ac field power. With proper segmentation, the ac field power could be utilized more efficiently and this can alleviate the requirement for medium damping which has been previously considered a critical limitation. The micro-magnetic modeling also shows that with segmentation optimization, recording signal-to-noise ratio can have very little dependence on damping for different recording linear densities.